[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100612210":3},{"organization":4,"outcomesModule":7,"designInfo":14,"detailedDescription":17,"studyPopulation":18,"armGroups":19,"interventions":13,"overallOfficials":22,"centralContacts":26,"locations":13,"responsibleParty":36,"collaborators":13,"id":40,"slug":13,"hasResults":41,"nctId":42,"briefTitle":43,"officialTitle":44,"acronym":13,"eligibilityCriteria":45,"healthyVolunteers":41,"sex":46,"minAge":47,"maxAge":13,"enrollmentInfo":48,"targetDuration":13,"studyType":51,"phases":13,"briefSummary":52,"conditions":53,"keywords":56,"overallStatus":59,"whyStopped":13,"lastUpdateSubmitDate":60,"lastUpdatePostDateStruct":61,"startDateStruct":64,"completionDateStruct":66,"leadSponsor":68,"locationsCount":13},{"fullName":5,"class":6},"Assiut University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":13},[9],{"measure":10,"description":11,"timeFrame":12},"To compare the diagnostic accuracy (sensitivity, specificity, PPV, NPV) of a 10 minute CTG versus a standard 30-minute CTG in fetal monitoring and well being","Using fetal acidemia defined as (umbilical venous pH \\\u003C 7.25) as reference in detecting fetal will being and comparing results with 10-min \\& 30-min CTG monitoring to evaluate diagnostic accuracy of both in detecting fetal acidemia.","Immediately after birth",null,{"allocation":13,"interventionModel":13,"interventionModelDescription":13,"primaryPurpose":13,"observationalModel":15,"timePerspective":16,"maskingInfo":13},"COHORT","PROSPECTIVE","In Egypt, labor wards in tertiary hospitals are often overcrowded with limited CTG machines and midwives. The requirement of a minimum 30-minute CTG trace creates bottlenecks in care and increases staff workload. Previous studies suggest that the first 10 minutes of a CTG may capture the essential features of fetal well-being. If validated, a shortened CTG could improve efficiency in high-volume maternity units without compromising neonatal outcomes. Using umbilical venous pH as the gold standard for fetal acid-base status, this study will directly compare the diagnostic accuracy of a 10-minute versus a 30-minute CTG protocol in low-risk laboring women. The aim is to evaluate whether a 10-minute CTG tracing is non-inferior to the standard 30 minute CTG in fetal assessment and predicting fetal acid-base status (umbilical venous pH) in term, low-risk pregnancies during the active first stage of labor.","All women who come to Women's Health Assiut university hospital in labor and meet the inclusion criteria after informed consent.",[20],{"label":21,"type":13,"description":13,"interventionNames":13},"women full term pregenancy in active stage of labor",[23],{"name":24,"affiliation":5,"role":25},"Elwani Eldremey Elsenousy, Professor","STUDY_CHAIR",[27,32],{"name":28,"role":29,"phone":30,"phoneExt":13,"email":31},"Soliman Mohamed Alazhary, Master","CONTACT","+20 1143883568","Soliman.alazhary@gmail.com",{"name":33,"role":29,"phone":34,"phoneExt":13,"email":35},"Seif Ahmed Ali, PHD","+20 1004971596","Seifali-2020@aun.edu.eg",{"type":37,"investigatorFullName":38,"investigatorTitle":39,"investigatorAffiliation":5,"oldNameTitle":13,"oldOrganization":13},"PRINCIPAL_INVESTIGATOR","Soliman Mohamed Soliman Alazhary","Dr.Soliman Mohamed Alazhary","100612210",false,"NCT07250620","Comparison Between Using 10min CTG in Fetal Monitoring Instead of 30min Monitoring in Low Resources Overcrowded Hospitals.","Diagnostic Accuracy of 10-Minute Vs 30-Minute CTG in Intrapartum Fetal Monitoring.","Inclusion Criteria:\n\n* Singleton pregnancy.\n* Gestational age ≥ 37 weeks.\n* Vertex presentation.\n* Active first stage of labor (cervical dilation ≥ 4 cm).\n* Low-risk pregnancy (no hypertension, diabetes, IUGR, or other significant complications).\n\nExclusion Criteria:\n\n* • Multiple gestation.\n\n  * Known major fetal anomaly.\n  * Non-vertex presentation.\n  * Indication for continuous CTG (e.g., meconium-stained liquor, antepartum hemorrhage).\n  * Maternal refusal.","FEMALE","18 Years",{"count":49,"type":50},200,"ESTIMATED","OBSERVATIONAL","Cardiotocography (CTG) is a cornerstone of intrapartum fetal monitoring but requires a minimum of 30 minutes for a reliable trace, creating a significant bottleneck in high-volume, low-resource settings like Egypt As it is time-consuming and resource intensive. This leads to delays in care and increased workload for healthcare providers. A shortened, yet accurate, CTG protocol could drastically improve workflow and resource allocation without compromising fetal safety.",[54,55],"Normal Pregnancy","Labor Active Dilated Cm",[57,58],"CTG","Fetal monitoring","NOT_YET_RECRUITING","2025-11-23",{"date":62,"type":63},"2025-11-26","ACTUAL",{"date":65,"type":50},"2025-12-17",{"date":67,"type":50},"2026-12",{"name":5,"class":6}]