Comparison of Acoustic Variability Index (AVI) and Pulse Pressure Variation (PPV) for Predicting Fluid Responsiveness in Mechanically Ventilated Patients

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age19+
SponsorSignal House Co., Ltd.

About this trial

The goal of this clinical trial is to learn if a new medical device called ResQ works to predict fluid needs in adults undergoing surgery under general anesthesia. The main questions it aims to answer are:

* Can the Acoustic Variability Index (AVI) measured by ResQ predict if a participant needs more fluids as accurately as the standard arterial blood pressure-based method (PPV)? * Is the ResQ device safe to use during surgery? Researchers will compare the new method (AVI) to the standard method (PPV) to see if ResQ provides reliable information for managing patient fluids.

Participants will:

* Undergo their planned surgery as scheduled. * Have a soft probe placed in the esophagus to monitor heart and lung sounds. * Receive a set amount of intravenous (IV) fluid as part of their regular surgery care. * Have their heart function checked before and after the fluids are given.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adults aged 19 years or older.

If female, not pregnant or breastfeeding.

Scheduled for a planned surgery of major organs in the abdominal, retroperitoneal, or pelvic cavities (e.g., hepatobiliary and pancreatic, small intestine, large intestine, kidney, uterus) under general anesthesia with mechanical ventilation

Classified as American Society of Anesthesiologists (ASA) Class I, II, or III. (Note: Excluded regardless of class if any

Disqualifiers

Scheduled to receive mechanical ventilation in a volume-controlled or pressure-controlled mode in the operating room or intensive care unit, with an anticipated tidal volume of 6-8 mL/kg (Ideal Body Weight), respiratory rate of 8-14 breaths/min, and PEEP of 0-5 cmH2O

Scheduled for hemodynamic monitoring to measure the comparison indices during surgery

Able to understand the study's purpose and procedures and communicate clearly with the investigator and research staff

Voluntarily signed the written informed consent form before participating in the study

Trial population

The study population consists of adult patients at Asan Medical Center in Seoul, South Korea. Participants will be recruited from the patients scheduled to undergo elective major surgeries involving organs in the abdominal, retroperitoneal, or pelvic cavities (such as hepatobiliary, pancreatic, intestinal, renal, or uterine procedures). These patients will be receiving general anesthesia and mechanical ventilation and are expected to require continuous intraoperative hemodynamic monitoring as part of their standard surgical care.

Trial design

Design model

Case-only

Time perspective

Prospective

Treatments tested in this trial

  • Biological Signal Processing Device for Acoustic Variability Index

    Device

    A biosignal processing device that measures AVI and RR continuously in real-time. It analyzes heart and lung sounds collected via a general-purpose internal probe inserted into the patient's esophagus.

  • Patient monitor for pulse pressure variation

    Device

    A standard multi-parameter patient monitor used to measure the reference hemodynamic index, Pulse Pressure Variation (PPV), via an arterial catheter

  • Hemodynamic monitor for cardiac Output and stroke volume variation

    Device

    A specialized hemodynamic monitoring system used to measure the reference standard for fluid responsiveness: Cardiac Output (CO) and Stroke Volume Variation (SVV)

  • Patient monitor for pleth variability index

    Device

    A patient monitoring system used to measure the Pleth Variability Index (PVI) via a non-invasive sensor attached to the finger or toe

  • Anesthesia monitoring system for respiratory rate

    Device

    An anesthesia delivery and monitoring system used to provide the reference Respiratory Rate (RR) measurement based on end-tidal CO2 (EtCO2) waveforms during general anesthesia

Treatment groups

122 Participants
are divided into 1 treatment group
Group A: Mechanically Ventilated Surgical Patients (Paired-Comparison)5 interventions

Trial outcomes

Primary outcomes

1

Comparison of Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) between AVI and PPV for Predicting Fluid Responsiveness (Non-inferiority)

Assessed by calculating and comparing the Area Under the Curve (AUC) of the Receiver Operating Characteristic (ROC) curve for both indices to predict fluid responsiveness. The non-inferiority of AVI compared to PPV will be evaluated. Fluid responsiveness is defined as a Cardiac Output (CO) increase of 10% or more following a 500 mL fluid challenge.

Time frame
Baseline (assessed continuously for 3 minutes before fluid challenge) and 3 minutes after a 500 mL fluid challenge

Secondary outcomes

1

Concordance of Respiratory Rate (RR) between ResQ and Carestation 750

Assessed by evaluating the agreement of respiratory rate (RR) measurements between the ResQ device and the reference anesthesia workstation (Carestation 750).

Time frame
Baseline (assessed continuously for 3 minutes before fluid challenge) and 3 minutes after a 500 mL fluid challenge.
2

Comparison of Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) between AVI and PVI for Predicting Fluid Responsiveness

Assessed by calculating and comparing the Area Under the Curve (AUC) of the Receiver Operating Characteristic (ROC) curve for both indices to predict fluid responsiveness. Fluid responsiveness is defined as a Cardiac Output (CO) increase of 10% or more following a 500 mL fluid challenge.

Time frame
Baseline (assessed continuously for 3 minutes before fluid challenge) and 3 minutes after a 500 mL fluid challenge.
3

Comparison of Area Under the Receiver Operating Characteristic (ROC) Curve (AUC) between AVI and SVV for Predicting Fluid Responsiveness

Assessed by calculating and comparing the Area Under the Curve (AUC) of the Receiver Operating Characteristic (ROC) curve for both indices to predict fluid responsiveness. Fluid responsiveness is defined as a Cardiac Output (CO) increase of 10% or more following a 500 mL fluid challenge.

Time frame
Baseline (assessed continuously for 3 minutes before fluid challenge) and 3 minutes after a 500 mL fluid challenge
4

Diagnostic performance of AVI for fluid responsiveness (Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value)

Assessed by calculating sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) based on the optimal cut-off value determined by ROC curve analysis to evaluate the diagnostic performance of AVI.

Time frame
Baseline (assessed continuously for 3 minutes before fluid challenge) and 3 minutes after a 500 mL fluid challenge

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Signal House Co., Ltd.

Lead sponsor

Ministry of SMEs and Startups, Korea

Collaborator