[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100565933":3},{"organization":4,"outcomesModule":7,"designInfo":20,"detailedDescription":19,"studyPopulation":19,"armGroups":25,"interventions":32,"overallOfficials":19,"centralContacts":37,"locations":43,"responsibleParty":60,"collaborators":19,"id":64,"slug":19,"hasResults":65,"nctId":66,"briefTitle":67,"officialTitle":68,"acronym":19,"eligibilityCriteria":69,"healthyVolunteers":70,"sex":71,"minAge":72,"maxAge":19,"enrollmentInfo":73,"targetDuration":19,"studyType":76,"phases":77,"briefSummary":78,"conditions":79,"keywords":19,"overallStatus":46,"whyStopped":19,"lastUpdateSubmitDate":81,"lastUpdatePostDateStruct":82,"startDateStruct":85,"completionDateStruct":87,"leadSponsor":89,"locationsCount":90},{"fullName":5,"class":6},"University Institute of Maia","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":19,"otherOutcomes":19},[9,13,16],{"measure":10,"description":11,"timeFrame":12},"Knee extension and flexion isometric strength","Maximal isometric knee extension and flexion force will be measured using a handheld dynamometer (DynaMo Plus, VALD Performance, Brisbane, Queensland, Australia). For the knee extension assessment, participants will be in a seated position, whereas during the knee flexion evaluation, the participants will be in a prone position. To generate their maximal torque, the dynamometer chain length will be adjusted so that their knee angle will be at ∼60° and ∼30°, for the knee extension and flexion, respectively. Participants will then apply a maximal isometric effort, maintaining it for 5s, without any subsidiary body movements.","At the beginning and end of the study (Week 1 and Week 6)",{"measure":14,"description":15,"timeFrame":12},"Vertical jump","Jump height was evaluated using an optical measurement system (OptoJump, Microgate, Bolzano, Italy). The players will perform the countermovement jump, where they will begin from an upright position; a rapid downward movement to a knee angle of ∼90°, immediately transitioning to propel themselves upwards into the air.",{"measure":17,"description":18,"timeFrame":12},"Change of direction sprint","The Modified T-Test will be implemented to assess change of direction sprint. This evaluation has within itself directional changes such as forward sprinting, left and right-side shuffling, and backpedaling. Photocells (WhittyGate, Microgate, Bolzano, Italy) will be used for a more precise time count.",null,{"allocation":21,"interventionModel":22,"interventionModelDescription":19,"primaryPurpose":6,"observationalModel":19,"timePerspective":19,"maskingInfo":23},"NA","SINGLE_GROUP",{"masking":24,"maskingDescription":19,"whoMasked":19},"NONE",[26],{"label":27,"type":28,"description":29,"interventionNames":30},"Elastic Band Group","EXPERIMENTAL","Athletes that have participated in a bi-weekly elastic band resistance training program.",[31],"Other: EBT",[33],{"type":6,"name":34,"description":35,"armGroupLabels":36,"otherNames":19},"EBT","Elastic Band Resistance Training",[27],[38],{"name":39,"role":40,"phone":41,"phoneExt":19,"email":42},"Henrique Sousa, MSc","CONTACT","+351934551303","hsousa.dcd@umaia.pt",[44],{"facility":45,"status":46,"city":47,"state":48,"zip":49,"country":50,"countryCode":51,"cosmosGeoPoint":52,"geoPoint":57,"contacts":58},"University of Maia","RECRUITING","Maia","Porto District","4475-690 Maia","Portugal","PT",{"type":53,"coordinates":54},"Point",[55,56],-8.6199,41.23574,{"lat":56,"lon":55},[59],{"name":39,"role":40,"phone":41,"phoneExt":19,"email":19},{"type":61,"investigatorFullName":62,"investigatorTitle":63,"investigatorAffiliation":45,"oldNameTitle":19,"oldOrganization":19},"PRINCIPAL_INVESTIGATOR","Henrique Sousa","Principal Investigator","100565933",false,"NCT06648616","Impact of Elastic Band Resistance Training on Female Football Performance: A Pilot Study","Evaluating the Effects of Elastic Bands Resistance Training on Performance Parameters in Female Football Players: A Pilot Study","Inclusion Criteria:\n\n* be over 18 years of age;\n* belong in the senior level of an amateur or professional women´s football club;\n* play in one of the three Portuguese national women´s football leagues.",true,"FEMALE","18 Years",{"count":74,"type":75},10,"ESTIMATED","INTERVENTIONAL",[21],"The goal of this clinical trial is to assess the effects of a 6-week strength training program with elastic bands on several physical components in adult female football players. The main question it aims to answer is:\n\nWill a specific elastic band resistance training help improve some components of physical performance in adult female football players?\n\nParticipants will perform a bi-weekly elastic band resistance training, during a period of 6-weeks. This program will be incorporated into their in-season regimen, before their training session.",[80],"Physical Perfrormance Parameters","2024-10-16",{"date":83,"type":84},"2024-10-18","ACTUAL",{"date":86,"type":75},"2024-10",{"date":88,"type":75},"2025-01",{"name":5,"class":6},1]