[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100603070":3},{"organization":4,"outcomesModule":7,"designInfo":31,"detailedDescription":33,"studyPopulation":34,"armGroups":35,"interventions":30,"overallOfficials":30,"centralContacts":39,"locations":45,"responsibleParty":68,"collaborators":30,"id":70,"slug":30,"hasResults":71,"nctId":72,"briefTitle":73,"officialTitle":73,"acronym":30,"eligibilityCriteria":74,"healthyVolunteers":71,"sex":75,"minAge":76,"maxAge":30,"enrollmentInfo":77,"targetDuration":80,"studyType":81,"phases":30,"briefSummary":82,"conditions":83,"keywords":85,"overallStatus":48,"whyStopped":30,"lastUpdateSubmitDate":90,"lastUpdatePostDateStruct":91,"startDateStruct":94,"completionDateStruct":96,"leadSponsor":98,"locationsCount":99},{"fullName":5,"class":6},"Pontificia Universidad Catolica de Chile","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":30},[9],{"measure":10,"description":11,"timeFrame":12},"Differentiation of cancerous tissue from normal tissue","Specificity, sensitivity, and accuracy of the device and software in tissue classification","Evaluation will be conducted 2 months post-surgery, comparing the biopsy results with the classification made by the device.",[14,18,22,26],{"measure":15,"description":16,"timeFrame":17},"Applicability to the surgical workflow","Installation time and the surgeon's subjective assessment will be measured using the \"Device Applicability to Surgical Workflow\" survey, which comprises three questions for a total score of 3-15 points. The survey will be administered once to each surgeon.","The survey will be done 30 minutes after the conclusion of surgery and is estimated to require two minutes to complete.",{"measure":19,"description":20,"timeFrame":21},"Biocompatibility","Biocompatibility of the materials used will be assessed by documenting adverse reactions during the surgical procedure and the immediate postoperative period.","Adverse reactions will be evaluated from the moment of intervention up to 48 hours after the surgical procedure",{"measure":23,"description":24,"timeFrame":25},"Detecting volatile organic compounds in breast cancer tissue.","The device is capable of real-time detection of organic compounds, with a latency not exceeding 1.5 seconds, and exhibits variable response slopes depending on the specific volatile organic compounds to which it is exposed.","Measurement will occur intraoperatively from the surgeon's first electrosurgical incision until removal of the primary specimen-typically within the first hour of surgery. This timeframe applies to every analyzed procedure.",{"measure":27,"description":28,"timeFrame":29},"Complications associated with the use of the device","Late complications related to device use will be assessed through reported occurrences.","Complications associated with device use will be assessed during the late postoperative period, defined as 48 hours after surgery up to one month post-intervention.",null,{"allocation":30,"interventionModel":30,"interventionModelDescription":30,"primaryPurpose":30,"observationalModel":6,"timePerspective":32,"maskingInfo":30},"PROSPECTIVE","The study will consist of measuring gases emitted during surgery. Prior to this, the device will be trained in the detection and recognition of the most prevalent gases in cancerous tissue. This will enable the AI to detect and classify cancerous breast tissue from healthy tissue. The study will include patients with different types and subtypes of breast cancer, such as ductal carcinoma in situ invasive ductal carcinoma, invasive lobular carcinoma, triple-negative breast cancer, human epidermal growth factor receptor 2 positive breast cancer, and hormone receptor-positive breast cancer. These types and subtypes reflect the diversity and complexity of breast cancer and may influence the performance and accuracy of the BCGC device.\n\nDuring the clinical testing phase, the laboratory-acquired tissue detection capability will be evaluated in a real situation. For this, the device will be connected to a sterile PVC hose directly connected to a smoke extractor associated with the electrosurgical unit that will cauterize the tissues. To evaluate the sensitivity, specificity, and accuracy of the device, the AI's detection will be compared with the quick biopsy and the deferred biopsy of the surgical piece. For this, access will be obtained to the histological reports and the surgery will be recorded to identify margins.\n\nThe device will be calibrated once a month with gases of known nature, a maximum variability of 5% will be tolerated. If a greater variability is detected at the time of calibration, it will be changed to every 2 weeks. The information will be anonymized and stored on an SSD unit and will be deleted 5 years after the completion of the study.","The study will recruit women from all over Chile who are indicated for conservative breast cancer surgery. It is estimated that the majority of patients will be those from Santiago de Chile who receive care from professionals in the UC Christus Health Network and decide to have surgery at the UC CHRISTUS Clinical Hospital.",[36],{"label":37,"type":30,"description":38,"interventionNames":30},"Patients who have undergone conservative breast cancer surgery","This group will undergo an analysis of gases emitted by cauterization. This intervention will not modify the duration of the surgery, nor will it alter the patient's treatment and prognosis. The gases will be analyzed through the detection device, which will not have direct contact with the patient and will not influence the surgical outcomes of the resection surgery. The patient will be followed for 2 years through their clinical care records in the UC Christus health network, looking for the occurrence of disease recurrence.",[40],{"name":41,"role":42,"phone":43,"phoneExt":30,"email":44},"Maximiliano L Mariné","CONTACT","+56952084996","maxmarine@uc.cl",[46,60],{"facility":47,"status":48,"city":49,"state":50,"zip":51,"country":52,"countryCode":53,"cosmosGeoPoint":54,"geoPoint":59,"contacts":30},"Hospital Clínico UC CHRISTUS","RECRUITING","Santiago","Santiago Centro","8320000","Chile","CL",{"type":55,"coordinates":56},"Point",[57,58],-70.64827,-33.45694,{"lat":58,"lon":57},{"facility":61,"status":62,"city":49,"state":63,"zip":64,"country":52,"countryCode":53,"cosmosGeoPoint":65,"geoPoint":67,"contacts":30},"Facultad de medicina UC","ACTIVE_NOT_RECRUITING","Santiago Metropolitan","8330191",{"type":55,"coordinates":66},[57,58],{"lat":58,"lon":57},{"type":69,"investigatorFullName":30,"investigatorTitle":30,"investigatorAffiliation":30,"oldNameTitle":30,"oldOrganization":30},"SPONSOR","100603070",false,"NCT07131735","Intraoperative Detection of Breast Cancer by Electrosurgical Gas Analysis and Artificial Intelligence","Inclusion Criteria:\n\n* Histologically confirmed diagnosis of malignant breast cancer\n* Scheduled for BCS at the Hospital UC\n* Able and willing to provide informed consent\n\nExclusion Criteria:\n\n* Pregnant or lactating women\n* Patients with known hypersensitivity or allergy to any component of the BCGC device\n* Participation in another interventional clinical trial within 30 days prior to enrolment","FEMALE","18 Years",{"count":78,"type":79},30,"ESTIMATED","3 Years","OBSERVATIONAL","The aim of this clinical trial is to assess the feasibility of training a device capable of distinguishing various gases emitted by tissues cauterized by an electrosurgical unit during a breast cancer resection surgery. The patients to be enrolled will be women over 18 years old diagnosed with breast cancer who are indicated for conservative breast cancer resection surgery as treatment.\n\nThe main questions to be answered are:\n\nThe specificity and sensitivity of the device in detecting margins compromised with tumor cells in resection surgeries.\n\nEvaluate the applicability of the device in breast cancer surgeries for real-time detection of margins.\n\nEvaluate the differences in the pattern of gases emitted in tumor cells vs normal cells.\n\nBy consenting, the study patients will allow the investigative team to access the clinical record, results of images, post-surgical biopsies, recording of the surgery while preserving the patient's anonymity, and the installation of the gas detection device. This device does not alter the flow of the surgery and does not add additional risk to it.",[84],"Breast Cancer",[84,86,87,88,89],"odors and cancer","breast surgery","intraoperative margin assistant","artificial intelligence","2025-08-12",{"date":92,"type":93},"2025-08-20","ACTUAL",{"date":95,"type":93},"2023-12-18",{"date":97,"type":79},"2025-09-18",{"name":5,"class":6},2]